投稿问答最小化  关闭

万维书刊APP下载

超灵敏钇改性氧化锡薄膜亚ppb级NO2探测器

2023/3/20 15:27:54  阅读:105 发布者:

一、文献题目:

Ultrasensitive yttrium modified tin oxide thin film based sub-ppb level NO2 detector

二、文献信息:

期刊:Sensors and Actuators B: Chemical

影响因子:IF  9.221

发表日期:2020-12-02

DOI10.1021/acsami.0c12259

单位:Department of Physics, Guru Nanak Dev University, Amritsar, 143005, India

三、文献内容:

1Undoped and Y-doped SnO2 thin films-based gas sensors have been fabricated.

2Highly reactive in-plane oxygen vacancies were created due to Y-doping.

3For 3 wt% Y-doped SnO2 sensor, enhanced room-temperature selectivity and high response was obtained towards NO2.

4The fabricated sensors were able to detect sub-ppb level of NO2.

四、结果与讨论

通过共沉淀的方法合成了纯的、135wt%Y掺杂的SnO2纳米颗粒,制造了具有亚ppb检测极限的SnO2薄膜室温(RT)传感器。如图所示,纯SnO2膜由相互连接的晶粒组成且是光滑的,随着Y掺杂量的增加,晶粒开始分离并且尺寸减小。此外,Y的过量掺杂会破坏薄膜的颗粒结构从而出现颗粒团聚。根据1PS1YS3YS5YSSnO2膜的XRD表征,Y3+取代了主体晶格中较小的Sn4+:掺杂膜中的峰值强度随着掺杂含量的增加而显著降低,峰位置向低角度移动,峰宽度变宽。

SnO2中掺杂合适量的Y能够增加氧空位(OV)的数量,从而促进大气氧分子的吸附,进而增强传感响应。如图所示,不同Y掺杂量的SnO2膜的O 1SXPS光谱可以去卷积为OⅠ、OⅡ、OⅢ峰,分别对应于晶格氧、空位氧(OV)和化学吸附氧物种。其中,OV以及化学吸附氧的相对量取决于SnO2膜中Y的浓度。当Y掺杂量为3 wt%时,样品中的OV的量从未掺杂时的6.01%增加到10.81%

纯的和Y掺杂SnO2膜的气敏测试结果如下:在室温下,所有传感器的响应随着Y掺杂而增强,对于3%Y掺杂传感器响应达到峰值。与50150nm厚的膜相比,100nm厚的基于膜的传感器显示出更高的灵敏度。Y3+离子的掺入能够促进NO2分子在SnO2表面上的吸附和解吸,其中基于100nm膜厚度的传感器(3YS)表现出了1445%的最高响应值。该传感器在室温下对100ppm NO2的响应和恢复时间分别为8min12min,检测限为0.6ppb。在高湿度水平下,传感器的响应值、响应和恢复时间仍能保持稳定,在实际应用中具有很高的潜力。

转自:“科研一席话”微信公众号

如有侵权,请联系本站删除!


  • 万维QQ投稿交流群    招募志愿者

    版权所有 Copyright@2009-2015豫ICP证合字09037080号

     纯自助论文投稿平台    E-mail:eshukan@163.com